Nortel-networks 450 User Manual Page 83

  • Download
  • Add to my manuals
  • Print
  • Page
    / 290
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 82
BayStack 450 10/100/1000 Series Switches
302401-D Rev 00
1-57
MultiLink Trunks
MultiLink Trunks allow you to group up to four switch ports together to form a
link to another switch or server, thus increasing aggregate throughput of the
interconnection between the devices (up to 800 Mb/s in full-duplex mode). You
can configure up to six MultiLink Trunks. The Trunk members can reside on a
single unit or on multiple units within the same stack configuration as a
distributed trunk. MultiLink Trunking software detects misconfigured (or broken)
trunk links and redirects traffic on the misconfigured or broken trunk link to other
trunk members within that trunk.
You can use the Trunk Configuration screen to create switch-to-switch and
switch-to-server MultiLink Trunk links (see Figures 1-38
and 1-39).
Figure 1-38
shows two trunks (T1 and T2) connecting switch S1 to switches S2
and S3.
Figure 1-38. Switch-to-Switch Trunk Configuration Example
S1
S2
S3
BS45026A
T1
T2
F
F
kombk.book Page 57 Tuesday, June 29, 1999 3:25 PM
Page view 82
1 2 ... 78 79 80 81 82 83 84 85 86 87 88 ... 289 290

Comments to this Manuals

No comments