Installation Guide For the 5000i® Scanner NCS Pearson Publication Number 202 234 027
Optional Equipment... 33 System Printers...
Introduction This manual describes how to install the 5000i scanner. The scanner is typically used with a computer, a color monitor, a printer, and c
x 5000i Scanner Installation Guide
1. Scanner Overview This chapter presents an overview of the 5000i scanner and provides information on how to receive technical support for hardware
• The output hopper { XE "Output hopper" }receives the forms that are successfully scanned. When the scanner starts, the output hopper is
tiger009 Figure 1 – 2: Scanner Standalone Configuration Customer Support When you call NCS Pearson Customer Support{ XE "Scanner, 5000i:Custome
Technical Support for Software Problems When you have questions concerning the scanner system software, call NCS Pearson Customer Support. Before cal
Chapter 1. Scanner Overview Page 5
2. Scanner Installation This chapter describes how to set up and install the standalone 5000i scanner{ XE "Installation:Scanner" },{ XE &q
Installation The installation { XE "Scanner installation:Sequence of events" }sequence for the 5000i scanner includes: 1. Check the instal
− The temperature must be between 60o and 80o Fahrenheit (16 - 27 C). − The humidity must be between 40% and 60% (non-condensing). • Heat { XE &qu
Installing the Scanner The 5000i scanner is delivered to the customer shrink-wrapped and up-right on its own four casters. Roll the scanner to its pe
Checking the Voltage{ XE "Scanner installation:Check the voltage" } Before you plug the 5000i scanner into the designated wall outlet, the
Dedicated Ground A dedicated isolated/insulated ground { XE "Dedicated ground specifications" }for the 5000i system must be provided. If po
then another code-approved method must be used. (The isolated ground conductor is noted in the National Electrical Code{ XE "National Electrical
Ground-To-Neutral Specifications{ XE "Conductor:Specifications, ground-to-neutral" \t "See" }{ XE "Voltage:Ground-to-neutral
Site Power Wiring Recommendations The table below describes the conditions{ XE "Scanner installation:Site power wiring recommendations" } {
Electrical Requirements{ XE "Scanner installation:Electrical requirements" } The steady-state line-to-neutral voltage should be maintained
Logic Voltage Check-out Procedure{ XE "Adjustment:Multivolt logic power supplies" } The outputs of the power supplies { XE "Power supp
the adjustment potentiometers. The power supplies that may require checkout and periodic adjustments are: • +12V, 250W, Solenoid{ XE "Solenoid:
Installation Guide For the 5000i® Scanner NCS Pearson Publication Number 202 234 027
+5, +/-15V Logic Supply+5V LED SupplyPrinter TransformerPWRC Board Solenoid and DC Motors SupplySolenoidBoostVoltageTiger040 Figure 2 – 1: Locat
Chapter 2. Scanner Installation Page 19
3. Installation of Computer and Other Peripherals This chapter provides information on setting up and { XE "Computer installation:Introduction&
Standalone Installation The 5000i scanner in a standalone configuration requires a computer, a monitor, a keyboard, a mouse, and a table (for the mon
• Attach one end of the Hobbes to Catgut cable assembly (flat, 40-pin polarized cable) to the Hobbes board{ XE "Hobbes board" \i }. • Set
slot. Do not connect to the 15-pin connector on the system board. 6. Complete installation of the 50-pin high density ribbon cable - the Camera Cont
Board/Connector Relationship Figure 3-2 illustrates the relationship between PC boards { XE "Standalone:Board/connector relationship" }atta
Network Installation{ XE "Scanner, 5000i:Network configuration" } The 5000i scanner in a network configuration requires an NCS Pearson-supp
• Ensure that the SIMMs on the Catgut II board are fully seated. Page 26 5000i Scanner Installation Guide
• Attach one end of the Hobbes to Catgut cable assembly (flat, 40-pin polarized cable) to the Hobbes board. • Set the Catgut board into the PCI slo
Copyright © 1996, 1997, 1998, 2001 NCS Pearson, Inc. All rights reserved. Printed in the United States of America. No part of this book
6. Complete installation of the 5 BNC/15-pin DIN cable - from the bulkhead (for the monitor) to the back of the computer. • One end (5 BNC end) is
Keyboard and Mouse{ XE "Network installation:Keyboard and mouse" } 1. Plug the keyboard cable into the port labeled KEYBOARD located behin
Board/Connector Relationship Figure 3-4 illustrates the relationship between PC boards{ XE "Network installation:Board/connector relationship&qu
cables already connected to the appropriate boards. Because the computer is shipped separately, you must install the computer and then make the neces
Figure 3-5 is a schematic illustrating a typical configuration; it may change depending on version of computer. Table 3-1 lists cables, part numbers,
Optional Equipment Optional equipment includes system printers and the Bar Code Reader. System Printers Cabling for system printers is slightly diffe
Bar Code Reader The optional Bar Code Reader { XE "Bar code installation" } is usually installed at NCS Pearson Manufacturing. It can also
Chapter 3. Computer and Peripherals Installation Page 35
4. Scanner Checkout This chapter discusses the procedures for scanner checkout, pre-installed system software, system verification and backup, and
You need to have 128 MB of paging space for the file server and 32 MB of paging space for each edit workstation. Chapter 4. Scanner Checkout Page 3
Revision Log Tab/Rev Date Description 12/96 Manual Released 019 04/97 Deleted all instances of the term NCS where it refers to the product
Before updating the 5000i scanner software, make sure that the following are installed and configured for version x.x. • Windows NT operating system
5. Demonstrate periodic maintenance. • Clean the upper transport bed. • Clean the lower transport bed. • Clean the outer turnaround. • Clean the
Page 40 5000i Scanner Installation Guide
Index + E +12.5V power supply. See Power supply, +15V Electrical outlet, 10 Electrical outlet, convenience. See convenience outlet Environmental re
N National Electrical Code, 9 NEC. See National Electrical Code Network installation Board/connector relationship, 24 Computer, 20 Connecting to a ne
iv 5000i Scanner Installation Guide
Preface This manual describes how to set up and install the NCS Pearson™ 5000i scanner. This manual does not document how to install and configure
vi 5000i Scanner Installation Guide
Table of Contents 1. SCANNER OVERVIEW ........................ 1 Overview of