Install filter and NTND26 cable (for MSDL and DCHIP cards in different Large System equipment
rows) 203
2
Install the 15-pin I/O panel filter connector on the inward side of
the bracket.
3
Obtain the correct length of the NTND26 DCHI Interface Cable
Assembly to reach from the D-Channel port connector on the
faceplate of the MSDL card to the outward side of the 15-pin filter
connector installed in the I/O panel of the IPE Module that contains
the DCHIP card.
The NTND26 DCHI Interface Cable Assembly is available in the
following lengths:
NTND26AA 6 ft.
NTND26AB 18 ft.
NTND26AC 35 ft.
NTND26AD 50 ft.
4
Connect the appropriate NTND26 cable assembly to the D-Channel
port connector on the faceplate of the MSDL card and to the outward
side of the 15-pin filter connector installed in the I/O panel of the IPE
Module that contains the DCHIP card.
5
Use the NTMF04BA Extension Cable to connect the DCH (P5)
connector of the NTCW84KA to the inward side of the 15-pin I/O
panel filter connector.
—End—
Small System cable installation
Follow the steps in Procedure 13 "Installing cables on Small Systems" (page
203) for Small System cable installation.
Procedure 13
Installing cables on Small Systems
Step Action
1
Set the switches and jumper plugs in the NTAK02 SDI/DCH card as
shown. See Table 45 "NTAK02 SDI/DCH switch settings for IP Trunk
3.01 (and later) DCHIP" (page 204) and Table 46 "NTAK02 SDI/DCH
jumper settings for the IP Trunk 3.01 (and later) DCHIP" (page 204).
Nortel Communication Server 1000
IP Trunk Fundamentals
NN43001-563 02.01 Standard
Release 5.5 21 December 2007
Copyright © 2007, Nortel Networks
.