Nortel Networks Optivity Switch User Manual Page 115

  • Download
  • Add to my manuals
  • Print
  • Page
    / 192
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 114
Chapter 5 Using MultiLink Trunking Manager 115
Using Optivity Switch Manager, Release 1.1.0.0
Viewing MLT port information
To view port information as you configure an MLT:
The Port dialog box opens (Figure 49).
Table 35 Insert MLT dialog box items for two nodes
Section Item Description
Node 1 Node IP address of the first network device to be configured
on an MLT.
Id Unique identifier for the MLT that is automatically
assigned by MultiLink Trunking Manager.
Name User-defined name of the MLT. (When you type the
name for one node, the name is automatically added to
the other node.)
Ports Ports enabled on the MLT.
Type One of the following types of MLT:
Access
Trunk
The default is Access.
VlanIds VLAN IDs found on the device.
Node 2 Node IP address of the second network device configured on
the MLT.
Id Unique identifier for the MLT that is automatically
assigned by MultiLink Trunking Manager.
Name User-defined name of the MLT. (When you type the
name for one node, the name is automatically added to
the other node.)
Ports Ports enabled on the MLT.
Type One of the following types of MLT:
Access
Trunk
The default is Access.
VlanIds VLAN IDs found on the device.
In the Insert MLT dialog box, point to a port number.
Page view 114
1 2 ... 110 111 112 113 114 115 116 117 118 119 120 ... 191 192

Comments to this Manuals

No comments